For 30 Adc, 40 Adc and 50 Adc ATevos

The C2 filter consists of a single capacitor with two wires that connect to the Power Board.

Preparation:

  • Shut down and lock out all power to ATevo.
  • Remove safety shield.
  • Locate C2 capacitor mounted to back panel near top left of the enclosure.

Removal of Existing Capacitor (C2x) Assembly:

  • Loosen screw on capacitor bracket at bottom of capacitor mounting and disconnect wires attached to capacitor from Power Board. Replacement C2 will have new wires with pre-crimped terminals.
  • Remove C2 capacitor.
The pos(+) and neg(-) wires have different terminals to eliminate the possibility of connecting in reverse polarity.

Installation of New C2 Capacitor Assembly:

  • Connect wires of new C2 capacitor assembly to Power Board.
  • Insert new C2 into capacitor bracket and tighten screw at base of capacitor.
  • Replace safety shield, close door and restart ATevo.

For 75 Adc and 100 Adc ATevos

The C2 filter is mounted next to the C1 filter capacitor(s) and connects to the C1 capacitor with a bus bar. Follow instructions in Section 16.3.6 for replacing both C1 and C2.

Last modified: 5 May 2021