Motor Data Left & Motor Data Right SDO – Indexes 0×4100 and 0×4101

The Motor Data SDOs make the Ai motor data available to the master controller. Each Ai motor (MDR or PGD) has internal memory that is written upon final manufacturing. This data includes serial number, manufacture date, roller dimensions, etc. The following table identifies each element available in these SDOs. Please note that the data for the Left Motor is at Index 0×4100 and the data for the Right Motor is at index 0×4101.

Subindex Item Data Type Data Description
1 Production ID INT Sequence number for the items manufactured on the manufacture day
2 Customer ID SINT Customer code
3 Roller Type SINT ASCII value indicating roller type:
  • A = Standard
  • T = Tapered
  • W = Wash down rated (IP66)
  • Z = Freezer rated (-30°C)
4 Motor Type SINT Value indicating Motor Type:
  • 0 = MDR
  • 1 = PGD
5 Tube Diameter SINT Tube diameter in millimeters (not applicable for PGD)
6 Speed Code/ Gearbox SINT Value indicating gear reduction:
  • If MDR the value is the catalog Speed Code
  • If PGD the value is the catalog Gear Ration
7 Interlock SINT ASCII value indicating roller to roller interlocking method:
  • A = Straight (No interlocking)
  • B = V Pulley
  • G = Dual Groove
  • H = Micro-V Pulley
8 Manufacture Month SINT Numerical value of the month of manufacture (1 thru 12)
9 Manufacture Month SINT Numerical value of the last two digits of the year of manufacture
10 Shaft SINT Internally coded numerical value
11 Tube Material SINT ASCII value indicating tube material/covering option:
  • A = Plain Steel
  • B = 3mm Black Rubber option
  • J = Stainless Steel
  • Q = 2mm PVC Sleeve option
  • W = 3mm Urethan Coating option
  • Z = Zinc (Standard ZAM Tube)
12 Motor Length INT MDR length in mm
13 Manufacture Day SINT Day of the month when manufactured (1 thru 31)
14 Manufacture Country SINT ASCII value indicating place of final assembly:
  • 0 = Europe
  • 1 = Japan
  • 2 = USA
15 Time DINT The amount of elapsed time in minutes the motor has been running
16 Time Current Limit DINT The amount of elapsed time in minutes the motor has been running
17 Time Overheat DINT The amount of time in minutes the motor has been running overheated
18 On/Off Cycles DINT The number of times the motor has been cycled on and off
19 Over Voltage Count DINT The number of times the module voltage has exceeded 30V
20 Under Voltage Count DINT The number of times the module voltage has fell below 18V