Power Connection

Power connector is Degson DG245-5.0, 12 AWG (3.31 mm 2) Max wire size, 5-6 mm strip length

Electrical and Environmental Ratings

Power supply voltage 24.0V +/- 10%
Minimum Operating Voltage 21
Input Protection Rating Class III
Standby current consumption < 70mA
Maximum Operating Voltage 30V
Storage temperature -40ºC to 120º C ( -40ºF to 248ºF)
Ambient Operating temperature 0ºC to 50ºC ( 32°F to 122°F)
Humidity 5% to 95% non-condensing
Vibration 0.152 mm (0.006 in.) displacement, 1G peak
Mechanical Shock 20G peak for 10ms duration (1.0 ms)
Enclosure IP Rating IP54
Maximum peak current 2.4A

I/O Port Inputs

Each MotionLinx-IO module is equipped with two 4-pin female and two 4-pin male M8 style I/O Ports. Pin 2 and Pin 4 of each of these is master controller configurable to be either an input or an output. Any I/O Port pins configured as inputs by default are auto-sensing for the connected circuit type of either PNP or NPN such that both sourcing and sinking current will activate the input.

Both Left and Right Sensor ports utilize load detection circuits between the +24V (Pin 1) and Gnd (Pin 3). This circuit provides input to the processor such that sensor detected status can be known.

Inputs ●  PNP/NPN Auto-Sensing (Default)
●  Up to 2 Inputs per Port – Up to 8 Inputs per module
●  Master controller configurable for Push-Pull operation
Minimum ON current 1.5mA
Maximum OFFcurrent 0.4mA
Leakage current < 0.2 mA
Short Circuit protection (per side) 500mA max

I/O Port Outputs

Each MotionLinx-IO module is equipped with two 4-pin female and two 4-pin male M8 style I/O Ports. Pin 2 and Pin 4 of each of these is master controller configurable to be either an input or an output. When configured as an Output, the following chart applies:

Outputs PNP Sourcing Only
Output count Up to 8
Maximum current per Output 300mA
Short Circuit protection threshold per Output 500mA