The motor speed is set by the ON or OFF state of DIP switches 1 through 5.

No. SW 1 SW 2 SW 3 SW 4 SW 5 Frequency Motor RPM % of Max Speed
1 OFF OFF OFF OFF OFF 49 580 10.0%
2 OFF OFF OFF OFF ON 67 800 14.0%
3 OFF OFF OFF ON OFF 84 1000 17.0%
4 OFF OFF OFF ON ON 100 1200 20.5%
5 OFF OFF ON OFF OFF 117 1400 24.0%
6 OFF OFF ON OFF ON 134 1600 27.5%
7 OFF OFF ON ON OFF 150 1800 31.0%
8 OFF OFF ON ON ON 167 2000 34.5%
9 OFF ON OFF OFF OFF 184 2200 38.0%
10 OFF ON OFF OFF ON 200 2400 41.5%
11 OFF ON OFF ON OFF 217 2600 45.0%
12 OFF ON OFF ON ON 234 2800 48.5%
13 OFF ON ON OFF OFF 250 3000 51.5%
14 OFF ON ON OFF ON 267 3200 55.0%
15 OFF ON ON ON OFF 284 3400 58.5%
16 OFF ON ON ON ON 300 3600 62.0%
17 ON OFF OFF OFF OFF 317 3800 65.5%
18 ON OFF OFF OFF ON 334 4000 69.0%
19 ON OFF OFF ON OFF 350 4200 72.5%
20 ON OFF OFF ON ON 367 4400 76.0%
21 ON OFF ON OFF OFF 384 4600 79.5%
22 ON OFF ON OFF ON 400 4800 83.0%
23 ON OFF ON ON OFF 409 4900 84.5%
24 ON OFF ON ON ON 417 5000 86.0%
25 ON ON OFF OFF OFF 425 5100 88.0%
26 ON ON OFF OFF ON 434 5200 89.5%
27 ON ON OFF ON OFF 442 5300 91.5%
28 ON ON OFF ON ON 450 5400 93.0%
29 ON ON ON OFF OFF 459 5500 95.0%
30 ON ON ON OFF ON 467 5600 96.5%
31 ON ON ON ON OFF 475 5700 98.5%
32 ON ON ON ON ON 484 5800 100.0%