Pulseroller Products / Motor Rollers / Performance Data /
Senergy-IDC – 48.6 mm (1.9”) Dia.
Models ① A and Z
⌀ 48.6 mm
| Speed Code | Gearbox Stages |
Gear Ratio | Speed Range m/sec (ft/min) |
Torque N-M (in-lbs) |
Tangential Force N (lbf) |
|||||
| Min | Max | Rated | Accel | Starting | Rated | Accel | Starting | |||
| 15 | 3 | 45 | 0.03 | 0.33 | 2.7 | 4.2 | 10.3 | 114.8 | 170.8 | 425.9 |
| 5.9 | 65.0 | 23.9 | 37.2 | 91.2 | 25.8 | 38.4 | 95.8 | |||
| 20 | 33 | 0.04 | 0.45 | 2.0 | 3.0 | 7.5 | 84.0 | 125.0 | 311.7 | |
| 7.9 | 88.6 | 17.7 | 26.6 | 66.4 | 18.9 | 28.1 | 70.1 | |||
| 35 | 2 | 55/3 | 0.08 | 0.81 | 1.1 | 1.8 | 4.2 | 46.6 | 75.9 | 173.2 |
| 15.7 | 159.4 | 9.7 | 15.9 | 37.2 | 10.5 | 17.1 | 39.0 | |||
| 45 | 15 | 0.10 | 0.98 | 0.9 | 1.5 | 3.4 | 38.2 | 62.2 | 141.9 | |
| 19.7 | 192.9 | 8.0 | 13.3 | 30.1 | 8.6 | 14.0 | 31.9 | |||
| 60 | 11 | 0.13 | 1.34 | 0.6 | 1.1 | 2.5 | 20.0 | 45.5 | 103.9 | |
| 25.6 | 263.8 | 5.3 | 9.7 | 22.1 | 4.5 | 10.2 | 23.4 | |||
| 95 | 1 | 75/11 | 0.22 | 2.16 | 0.4 | 0.8 | 1.5 | 17.3 | 31.0 | 64.5 |
| 43.3 | 425.2 | 3.5 | 7.1 | 13.3 | 3.9 | 7.0 | 14.5 | |||
| Rated Current | Starting Current |
| 2.4A | 3.0A |
Torque Value Definitions
| Rated Torque | Torque that can be delivered by SENERGY-IDC for continuous use without overheating in environmental temperature of 25ºC. Average torque of start/stop operation should not exceed this value. |
| Starting Torque | Peak value of the motor stall torque |
| Accel Torque | Average torque which is present during the acceleration ramp up to set speed. This torque value can be used to calculate real acceleration time of an application taking into account all of the losses due to idler roller and/or belts. |
Identifiers such as ① and A refer to items in the Part Number Definition Senergy-IDC topic.