Module Hardware /
Technical Specifications
| Input Power Supply Requirements | ● 24.0VDC + / – 10% for 24V Models ● 48.0VDC +4% / – 10% for 48V Models |
|
| Input Protection Rating | Class III | |
| Standby Current Consumption | < 120 mA without Motor | |
| Minimum Operating Voltage | ● 21 V for 24V Models ● 35V for 48V Models |
|
| Maximum Operating Voltage | ● 30 V for 24V Models ● 50V for 48V Models |
|
| Storage Temperature | -25ºC to 70º C ( -13ºF to 160ºF) | |
| Ambient Operating Temperature | ● Standard Module: 0ºC to 40ºC ( 32°F to 104°F) ● Freezer Rated Module: -30ºC to 40ºC ( -22°F to 104°F) |
|
| Humidity | 5% to 95% non-condensing | |
| Vibration | 0.152 mm (0.006 in.) displacement, 1G peak | |
| Mechanical Shock | 20G peak for 10ms duration | |
| Enclosure IP Rating | IP54 | |
| Weight | Approximately 200g | |
| Environmental Pollution | Class 2 | |
| Altitude | up to 2000m | |
| Digital Input Minimum ON Current | 1.5 mA | |
| Digital Input Maximum OFF Current | 0.4 mA | |
| Digital Output Maximum Load | 20 mA | |
| Motor Ports | Supported Motor Types | Senergy-Ai |
| Motor PWM Frequency | ● 25 kHz +/- 0.1% for 24V Models ● 40 kHz +/- 0.1% for 48V Models |
|
| Max. Starting Current | ● 8A per port for 24V Models ● 4A per port for 48V Models |
|
| Rated Current | ● 3A per port for 24V Models ● 1.7A for 48V Models |
|
| Motor Protection | ● Coil-to-coil short ● coil-to-Vcc short ● overheating ● over-voltage ● under-voltage ● stall sensing and protection |
|
| Network | Type | 3 port integrated switch |
| Speed | 10Base-T / 100Base-TX Auto Detect | |
| Support | ● Back pressure flow control ● Auto Duplex ● Auto straight/crossover detect ● PAUSE frame support |
|
| Supported protocols | ● Modbus TCP ● Profinet IO ● Ethernet IP ● CCLink IEF Basic |
|