PLC Developers Guide / ZPA Mode Control / PLC Outputs for ZPA Mode /
ConveyStop and Clear Jams
| Register Name | Internal Address | Assembled PLC Address |
Description | ||
| ConveyStop Command Word | 4:0020 | M: 4:1619 E: O.Data [19] P: Byte 38 (Hi) P: Byte 39 (Lo) |
Integer Value | ||
| 0 = | No Command | ||||
| 1 = | Command local module’s Stop Group to go to Stopped State | ||||
| 2 = | Command local module’s Stop Group to Clear Stopped State | ||||
| Clear Sensor Jam Local Upstream Zone |
4:0109 | M: 4:1620 E: O.Data [20] P: Byte 40 (Hi) P: Byte 41 (Lo) |
Use when when Module Status Word #1 bit 05 is set indicating Sensor Jam | ||
| Transition value from 0 to 1 to send command to local upstream zone to clear sensor jam condition | |||||
| Clear Sensor Jam Local Downstream Zone |
4:0189 | M: 4:1621 E: O.Data [21] P: Byte 42 (Hi) P: Byte 43 (Lo) |
Use when when Module Status Word #2 bit 05 is set indicating Sensor Jam | ||
| Transition value from 0 to 1 to send command to local downstream zone to clear sensor jam condition | |||||