Single or small number of FACS sorted lymphocytes in 96-well plates (i.e., up to ~500 cells/sample)
- Prior to FACS, prepare 96-well plates with pre-aliquoted 5 µl of PBS and 2 U/µl of RNasin per well. Note: This ensures the cells are suspended in the liquid, preventing them from getting stuck to the tube surface and dehydrating.
- Immediately after sorting, remove the plate from the motorized stage and seal it to prevent desiccation. Note: The plastic plate can absorb nucleic acids if it gets too dry.
- Seal the plate with a heat seal, e.g., Optically Clear Heat Seal, Bio-Rad, Cat. 1814030, in combination with Bio-Rad PX1 PCR Plate Sealer, Cat 181-4000, or a seal designed for storage up to -80°C (e.g., Microseal “C” Film, Bio-Rad, Cat. MSC-1001). Note: This prevents the seal from detaching during storage and shipment, which can expose the cell to lower pH and cause cell death.
- Then, briefly centrifuge the plate for 10-15 seconds to propel any drops on the side walls into the water. Label the plate, place each plate in an individual Ziplock bag, and store the plate at -80°C.
- Place the plates (which are inside the Ziplock bag) inside a cardboard box or case and secure it with tape. Provide information indicating what samples are in each plate and what wells were used for sorting, and complete the DriverMap single-cell AIR Sample Submission Form.
DirectCell AIR Assay for 500-50,000 purified lymphocytes
- Collect cells in 10 μL of 1xPBS plus 2 U/ul of RNAsin, aliquoted in 1.5-ml test tubes. Note: Avoid collecting cells in media or PBS with a high concentration of BSA (e.g., more than 0.1%).
- Spin down the test tubes at low speed (e.g., 500g for 5 min) to collect cells.
- Put the test tubes in a cardboard box and a Ziplock bag, freeze, store at -80°C, and ship on dry ice. Clearly label each tube with numbers (from 1 to X), and a short name (at most, 6-8 printed alphanumeric characters), and send us the DriverMap AIR Sample Submission Form with the sample names.
AIR assay for 1,000-100,000 lymphocytes
- For larger cell samples with more than 1,000 lymphocyte cells, we recommend sorting cells in 1.5-ml test tubes with 0.35 mL of RLT+ buffer (Qiagen Cat. No.1053393)
- Spin down the test tubes at low speed (e.g., 500g for 5 min) to collect cells.
- Put the test tubes in a cardboard box and a Ziplock bag, freeze, store at -80°C, and ship on dry ice. Clearly label each tube with numbers (from 1 to X), and a short name (at most, 6-8 printed alphanumeric characters), and send us the DriverMap AIR Sample Submission Form with the sample names.
Shipment Information
Ship Samples To:
Attn: Alex Chenchik
Driver Map AIR Service
Cellecta, Inc.
320 Logue Ave
Mountain View, CA 94043
Tel: 650-938-3910