Technical_settings_guide control rules can also be ran in the background to check the BPEM/EMMA cases are still valid and even re-open any cases which may have been completed in error prior to the condition being applied.

Program name: /BTI/MDE_BPEM_CLOSURE_MDR

This program is designed within our Node 5 framework and the technical settings need to be defined.

You can find the instructions on setting up the technical settings here:

Technical settings guide

This program can be executed on-line or in the batch run.

Once the program has been executed the selection screen as follows will be displayed:

Options available:

Case Category – Specific category types can be entered here if the program should only be run for certain case categories. If this field is left blank all categories that have been configured will be checked.

Completion date – The completion date of the BPEM/EMMA cases can be entered to restrict the data to be checked and only run the rules against cases completed on a particular date or date range.

Check box options:
Complete cases – If this is selected any cases checked whereby the rules are met will be mass completed by the program.
Reopen cases – If this is selected any cases that have been completed already however the rules are not met will be re-opened.
Confirm completed cases – Cases in status completed will be set to confirmed (this enables the status changes to be completed in bulk).

Test mode – If this option is selected the cases will be checked however no changes will be applied in the system.

Feedback

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.

Post your comment on this topic.

Please do not use this for support questions.
For customer support, please contact us here.

Post Comment