Motor Performance Setting Rated Current Starting Current Starting Current Duration Application
ECO 2.5A 3A 5 sec. General purpose use, maximum speed of MDR is available
BOOST 3.5A 5A 1.5 sec. Heavier load, maximum speed of MDR is reduced
BOOST 8
EZ-QUBE-HTBF-P, -N Only
3.5A 8A 1.5 sec. Staring heavier load from stop, maximum speed of MDR is reduced
PDU MAX
EZ-QUBE-HTBF-P, -N Only
8A - no limit Only for use with PDU-90 Lift/Lower MDRs, allows 6400 motor RPM



DIP Switch settings for EZ-QUBE-HTBF-P, -N

Motor Performance Switch 5 Switch 6
ECO OFF OFF
BOOST ON OFF
BOOST 8 OFF ON
PDU MAX ON ON