Tag Name Data Type Module Register Bit Description
O_Clear_Motor_Error BOOL 4:0022 0 Clear Motor Error Left & Right
O_Enable_Module INT - AOI Logic 1 – Move Reset Counter from I.Data(8) to O.Data(8)
O_Mtr_Dig_Ctrl_Clear_OverCurrent_Left BOOL 4:0060 15 1 = Clear Over-current error
O_Mtr_Dig_Ctrl_Clear_OverCurrent_Right BOOL 4:0084 15 1 = Clear Over-current error
O_Mtr_Dig_Ctrl_Dig_Outputs_En_Left BOOL 4:0060 8 0 = Use port as Motor Control, 1 = Use port as Digital Output
O_Mtr_Dig_Ctrl_Dig_Outputs_En_Right BOOL 4:0084 8 0 = Use port as Motor Control, 1 = Use port as Digital Output
O_Mtr_Dig_Ctrl_Pin3_Left BOOL 4:0060 0 Digital Output Control (1 – energized, 0 – clear)
O_Mtr_Dig_Ctrl_Pin3_Right BOOL 4:0084 0 Digital Output Control (1 – energized, 0 – clear)
O_Mtr_Dig_Ctrl_Pin4_Left BOOL 4:0060 1 Digital Output Control (1 – energized, 0 – clear)
O_Mtr_Dig_Ctrl_Pin4_Right BOOL 4:0084 1 Digital Output Control (1 – energized, 0 – clear)
O_Mtr_Dig_Ctrl_Pin5_Left BOOL 4:0060 2 Digital Output Control (1 – energized, 0 – clear)
O_Mtr_Dig_Ctrl_Pin5_Right BOOL 4:0084 2 Digital Output Control (1 – energized, 0 – clear)
O_Mtr_Dir_Left BOOL 4:0260 8 On = Run in Opposite of Config. Dir.
O_Mtr_Dir_Right BOOL 4:0270 8 On = Run in Opposite of Config. Dir.
O_Mtr_Run_Left BOOL 4:0260 0 On = Run
O_Mtr_Run_Right BOOL 4:0270 0 On = Run
O_Mtr_Speed_Left INT 4:0040 - Value in 0.1% units of motor %PWM
O_Mtr_Speed_Right INT 4:0064 - Value in 0.1% units of motor %PWM

Feedback

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.

Post your comment on this topic.