Please note that by default and without any intervention, the most downstream zone will always try to discharge product. To control this, you need to utilize the AUX signal for the most downstream zone as an Accumulate input.

Assuming the most downstream zone is connected to the right side of the module; we set the Right AUX to Accumulate(DI) from the drop-down box and make sure we click the DOWN arrow to indicate that the Right AUX signal is to be associated with the Downstream Zone. When the Right AUX signal is energized, the downstream zone will stop when an item arrives on its sensor

Feedback

Was this helpful?

Yes No
You indicated this topic was not helpful to you ...
Could you please leave a comment telling us why? Thank you!
Thanks for your feedback.

Post your comment on this topic.