Steps for resolution:

  1. Ensure foaming is not causing a false ‘Low Tank Level’ alarm. Do this by turning the sprayers off, letting sit idle for 1-minute, and checking tank level again.
  1. Ensure float switch is freely moving. To gain access to the float switch follow steps 1-5 of the Routine Maintenance section.
  1. If foaming is the cause, follow resolution steps for Defoamer Required


  1. If foaming is not the cause, in Manual Mode click the DOSE button. When full the machine will stop dosing automatically.
  1. In the Alarms and Warnings screen hit the CLEAR button

If the issue persists please Request Technical Support