An undefined reference error may occur for a specific global variable when executing a test after importing the integration test data, which was performed well in the past. If a ‘Not Found element’ message is displayed when you click ‘Global Variable’ in the ‘Test Info’ of the test in which the error occurred, the TU of the global variable may have been changed due to code modification. If you change the related file in the ‘Configuration’ tab of the test to the source file that the TU of the global variable was modified, you can check that the test works normally.