Module Status LEDs Blinking Green with unexpected results


Module Status LED is Blinking or Flashing Red

  • Make sure there are no other Ethernet devices (PC’s, Switches, Scanners, etc.) connected between any of the module on your network. The Auto-Configuration procedure aborts when it encounters a non ConveyLinx device along the network path before reaching the last module. ConveyLinx-ECOs up to that point should be configured properly but the remaining modules will not.
  • When removing a ConveyLinx-ECO from an existing configured network that is already operational; be sure to wait 1 or 2 minutes to allow the Ethernet Switches on the modules to reset their MAC Address ARP table before attempting a new Auto-Configuration procedure