The ConveyLinx-ECO module provides the Senergy ECO performance. The ConveyLinx-ECO module has an associated rated current that the motor will draw at rated torque and maximum speed as well as an associated allowed current draw that is available for a period of time upon the initial starting of the motor. Theses current values and starting times are shown in the following chart:
ECO | |
---|---|
Power supply load per Motor Port at rated torque at maximum speed | 2.5 A |
Power supply load per Motor Port during motor starting period | 3.0 A |
Duration of motor starting period | 5.0 sec |
このトピックへフィードバック