The TCP/IP launcher can be used to control a Hippotizer server using TCP/IP strings to carry out a number of system functions. Primarily you can launch different shows from the show manager or choose to close ZooKeeper or Engine applications.
Adapter
Select network adapter for the TCP/IP launcher to listen on.
Port
Select a port for the TCP/IP launcher to listen on.
Enabled
Toggle the TCP/IP launcher On/Off
Auto-Start
Have the TCP/IP launcher start with the hippo launcher or only through manually enabling.
TCP/IP Launcher Syntax
Command | TCP String | Example |
---|---|---|
Start Engine | <StartEngine:%SHOW-NAME%> |
<StartEngine:MyFirstShow> |
Start ZooKeeper | <StartZookeeper:%SHOW-NAME%> |
<StartZookeeper:MyFirstShow> |
Start Show | <StartShow:%SHOW-NAME%> |
<StartShow:MyFirstShow> |
Shutdown Show | <ShutdownSoftware> |
<ShutdownSoftware> |
Show current show | <CurrentShow> |
<CurrentShow> |
Show all available shows | <AvailableShows> |
<AvailableShows> |
Help Documentation | <Help> |
<Help> |
Post your comment on this topic.