With the Nevis+ unit, additional EDID management features are released to help manage and maintain this aspect of output configuration within the Hippotizer software. This is only available on Nevis+ units.
HippoLauncher Automation Process
On HippoLauncher start-up it automate the EDID Emulation process by inspect the connected and currently emulated outputs and help you set your unit up. Below is a table explaining the configuration during HippoLauncher start and what happens:
ZooKeeper Connected | ZooKeeper Emulated | Output Connected | Output Emulated | What Happens |
---|---|---|---|---|
No | No | No | No | ZooKeeper will be emulated as 1920×1080@60Hz |
Yes | No | No | No | The connected EDID for ZooKeeper will be emulated |
No | Yes | No | No | No change |
Yes | Yes | No | No | No change |
No | No | Yes | No | ZooKeeper will be emulated as 1920×1080@60Hz. Connected Output EDID will be emulated |
Yes | No | Yes | No | The connected EDID for ZooKeeper will be emulated. Connected Output EDID will be emulated |
No | Yes | Yes | No | Connected Output EDID will be emulated |
Yes | Yes | Yes | No | Connected Output EDID will be emulated |
No | No | No | Yes | ZooKeeper will be emulated as 1920×1080@60Hz |
Yes | No | No | Yes | The connected EDID for ZooKeeper will be emulated |
No | Yes | No | Yes | No change |
Yes | Yes | No | Yes | No change |
No | No | Yes | Yes | ZooKeeper will be emulated as 1920×1080@60Hz |
Yes | No | Yes | Yes | The connected EDID for ZooKeeper will be emulated |
No | Yes | Yes | Yes | No change |
Yes | Yes | Yes | Yes | No change |
In short the software will ensure there is always a ZooKeeper present even if a screen cannot be left physically connected. This is to ensure that in the case of a Windows pop-up, it will be posted onto the emulated ZooKeeper screen and not post over the output. It also means that units can be remotely accessed via a VNC solution and will have a virtual canvas within Windows for the ZooKeeper software instead of just having the outputs viewable remotely. In regards to the output connector, it will only automatically emulate if there is a physical connection and no current emulation on it.
Removing Emulation
The automated EDID emulation process will never remove emulation, so it is recommended practice to remove all emulation at the end of the show/installation so the machine is fresh on the next setup. This can be done in a numbers of ways including using the new Screen Management system in HippoLauncher, or with HippoLauncher open use the global shortcut CTRL + SHIFT + E to remove all emulation.
Whilst Engine Is Running
The process will also not run whilst the engine is started to prevent output manager being disrupted in a live setting.
Turning off Automated EDID Emulation
On the Advanced Tab in HippoLauncher you can also set the process to no longer run on HippoLauncher start. This setting is saved, but will be lost on installing a new version of software.
Post your comment on this topic.