In environments running CT 3.7 or earlier, project analysis may fail if the project includes numerous reference files. To resolve this issue, export the source code and toolchain files together from the PC where the project was created. Import all exported files along with the CT project on the importing PC.
- Compress the source code and toolchain-related files included in the project and transfer them to the importing PC where you want to import the project.
- Extract the compressed file.
- Example extraction path:
C:\
- Example extraction path:
- Use [Import Project] feature to import the project.
- When importing, update the paths of source files and other resources to the extracted location. Then click the [Finish] button.
- Select [Preferences] > [ToolChain].
- Select the imported toolchain and click [Edit…].
- Locate and configure the Env Script, Compiler, Linker, Archiver, and System Headers from the extraction path specified in Step 2.
- Reanalyze and execute the test.