The target log collector is a server that collects target test results and sends them to CT 2024.06. Collecting target test results methods are largely divided into communication and file scanning. Supported communication protocols and scannable file formats are as follows.
Protocol | TCP, UDP, UART |
---|---|
File format | Target log(text), memory dump(Hex, Intel HEX) |
Installation
The target log collector is automatically installed when CT 2024.06 is installed.
Run
When [Use the default target log collector] is checked in [Preferences] -> [Target Test] -> [Target Log Collector], the target log collector starts collecting target test results.
If you use TargetLogCollector.zip after extracting it, run TargetLogCollector.exe in the unzipped directory at the Windows command prompt.
Settings
It can be set through the ‘settings.ini’ file in the target log collector installation path, and the options are as follows.
[LogReceiveServer] | Settings for receiving target test results |
---|---|
port | TCP, UDP communication port |
protocol | Communication protocol for receiving target test results |
timeout | Connection timeout |
lastString | String representing the end of the data |
serialPort | Serial communication port (Windows: COM#, Linux: /dev/ttyS#) |
baudRate | Serial communication settings |
dataBits | Serial communication settings |
stopBits | Serial communication settings |
parity | Serial communication settings |
flowControl | Serial communication settings |
[ScanLog] | Settings for file scanning |
dir | Directory to scan |
fileExtension | File extensions to scan(Scan all files if blank) |
[LogSendServer] | Settings for communication with CT 2024.06 |
port | Target log file transfer port |
Need more help with this?