Pulseroller Products / Pulse Gear Drive (PGD) 24V/48V / Performance Data /

Pulse Gear Drive (PGD-IDC) 24V Internal Drive Control


Performance Data

All Models


Nominal Gear Ratio Gearbox
Stages
Actual Gear Ratio Output Shaft Speed
RPM
Torque
N-M (in-lbs)
Min Max Rated Accel Starting
11 2 11 52 528 0.6 1.1 2.5
5.3 9.7 22.1
15 15 38 386 0.9 1.5 3.4
8.0 13.4 30.1
18 55/3 31 316 1.1 1.8 4.2
9.7 16.3 37.2
33 3 33 17 176 2.0 3.0 7.5
17.7 26.8 66.4
45 45 12 128 2.7 4.2 10.3
23.9 36.7 91.2

Rated Current Starting Current
2.5A 3.0A

Torque Value Definitions


Rated Torque Torque that can be delivered by the PGD for continuous use without overheating in environmental temperature of 25ºC. Average torque of start/stop operation should not exceed this value.
Starting Torque Peak value of the motor stall torque
Accel Torque Average torque which is present during the acceleration ramp up to set speed. This torque value can be used to calculate real acceleration time of an application taking into account all of the losses due to idler roller and/or belts.