Pulseroller Products / Pallet Handling 48V /

Performance Data


The following definitions apply to the information in this section:

Rated Torque Torque that can be delivered by the motor roller for continuous use without overheating in environmental temperature of 25ÂșC. Average torque of start/stop operation should not exceed this value.
Holding Torque Torque the motor roller can maintain to hold a position against a load indefinitely without overheating.
Accel Torque Average torque which is present during the acceleration ramp up to set speed. This torque value can be used to calculate real acceleration time of an application taking into account all of the losses due to idler roller and/or belts.
Max Torque Max torque is the momentary or intermittent maximum performance of the product. Overuse at his level without proper cooling periods may result in overheating of the motor.

Learn More:


Speed Range & Torque

Tangential Force