1. Place the device at the lift car, so as to be accessible to all the connectors of the Nayar Switch by the installer. The device must not be able to be manipulated by the elevator user.
  2. Connect the RJ45 cable from Nayar Switch LAN connector to the device which is desired to be supplied Internet connectivity, such as an Advertisim.
  3. Connect the two previously used wires of the travelling cable, where the machine room device was connected, to lift car Nayar Switch IPBus connector, considering the order of H and L cables.
  4. If it is desired to use the Nayar Switch in order to feed an electronic device, VOUT connector must be used. The polarity of the DC connector must be respected. It is highly recommended to use it to feed Advertisim devices.
  5. Connect the power supply cables to the VIN connector by means of the DC power connector. The polarity of the DC connector must be respected.