At the front panel of the device can be found the following information:
MicroUSB – VIN
Input for the power supply. So as to provide an input voltage of 5VDC through a microUSB connector, a DC-DC converter with the input range 7 – 50VDC is supplied.
Discover button
This button carries out two actions:
- Linking the device to the App: This action is fully explained on 3.- Configuration, installation and start-up.
- Linking to a Wi-Fi network created by another Nayar Systems device: For example, if there is a Nayar Switch installed, it is possible to connect to its Wi-Fi network, by pressing the Nayar Switch Discover button and then, the one of BVA.
SW
Two microswitches with the following functionalities:
1 | Activation / deactivation of CAN terminating resistors |
2 | Activation / deactivation of IPBus terminating resistors |
CAN ( * ) / IPBus ( * )
- CAN H and L: Reception of CAN frames from lift controller
- IPBus H y L: Processing IPBus frames to transmit data through two electrical wires.
(*) On current product versions, these functionalities are not available.