- Identify the buttons and the wiring that activates each button and its common contact.
- Prepare the necessary wiring for installing the device: power, relay connection and common contact wiring.
- Identify the connection wires of buttons to the device, depending on relay configuration at Net4Machines Smart Control App. Relay 1 common contact is independent from that of relay 2.
- Wire the corresponding contacts of the button to the pluggable terminal of 14 positions and connect to the BVA.
- Prepare the wiring for the power supply of the device. For productos versions v3.0 and older, it is necessary to supply power to BVA thanks to a DC-DC converter with a type B microUSB connector. The converter must be connected to an electrical line with a voltage between 7 – 50 VDC. Plug the converter microUSB to the BVA.
- Place the device at an isolated location from water and humidity.
- Use the complements supplied to fix the product if necessary.
- Connect the power supply of the facility and check that the power LED is powered on.